The CDN Mx is designed according to IEC/EN 61000-4-6, which specifies the design and performance of coupling/decoupling networks. The CDN Mx is applicable to single-phase 1-line/2-line/2-line, three phase 4-line/5-line power lines. Its load capacity is available for customer’s requirement.
Features:
> As per IEC 61000-4-6:2017;
> Applicable to unscreened power lines;
General Technical Parameters |
|
As per |
IEC 61000-4-6 |
RF Input Port |
BNC |
RF Input Power |
6 W |
Common-Mode Impedance |
150 kHz ~ 24 MHz:150 Ω±20 Ω 24 MHz ~ 80 MHz:150 Ω﹢60 Ω/-45 Ω 80 MHz ~ 230 MHz:150 Ω±60 Ω |
Dimension |
≤32 A: 170 mm(L)×115 mm(H) ×210mm(D) >32 A: 220 mm(L)×135 mm(H) ×407 mm(D) |
Weight |
Approx. 4.5 kg (subject to actual product) |
Model Number Selection:
Nos |
Model Number |
Technical Parameters |
1 |
CDN M2-100 |
L+N,100A 600VAC/1000VDC, EUT/AE 25mm2 , 150KHz-80MHz |
2 |
CDN M2M3-16 |
L+N/L+N+PE,16A 250VAC/400VDC , EUT/AE 4mm , 150KHz-230MHz |
3 |
CDN M1 |
L+N/L+N+PE,32A 250VAC/400VDC , EUT/AE 4mm , 150KHz-230MHz |
4 |
CDN M2M3 |
L+N/L+N+PE,32A 250VAC/400VDC , EUT/AE 4mm , 150KHz-230MHz |
5 |
CDN M3-100 |
L+N+PE,100A 600VAC/1000VDC,EUT/AE 25mm2 , 150KHz-80MHz |
6 |
CDN M4N-16 |
L1+L2+L3+N,16A 250VP-N / 400VP-P ,EUT/AE 4mm , 150KHz-230MHz |
7 |
CDN M4N-32 |
L1+L2+L3+N,32A 250VP-N / 400VP-P , EUT/AE 4mm , 150KHz-230MHz |
8 |
CDN M4PE-32 |
L1+L2+L3+PE,32A 250VP-PE / 400VP-P , EUT/AE 4mm , 150KHz-230MHz |
9 |
CDN M4N-75 |
L1+L2+L3+N,75A 1000VP-N / 1500VP-P , EUT/AE 25mm2,150KHz-80MHz |
10 |
CDN M5-32 |
L1+L2+L3+N+PE,32A 250VP-N / 400VP-P , EUT/AE 4mm , 150KHz-230MHz |
11 |
CDN M5-75 |
L1+L2+L3+N+PE,75A 1000VP-N/1500VP-P,EUT/AE 25mm2, 150KHz-80MHz |
12 |
CDN M3L |
L1+L2+L3 ,32A 400VAC/400VDC , EUT/AE 4mm , 150KHz-230MHz |
13 |
CDN M3L-75 |
L1+L2+L3 ,75A 1000VP-N / 1500VP-P , EUT/AE 25mm2,150KHz-80MHz |
Accessories(≤32 A) |
Calibration Connector, Test line, User manual |
Accessories(>32 A) |
Calibration adapter, Fan Battery Adapter, Test line, User manual |
Options |
Calibration adapter CDN 100KIT |