Technical Parameters |
|
|
Standard |
IEC 61000-4-5 |
|
Generator |
|
|
Test Voltage(open-circuit waveform) |
0.5 kV ~ 10.0 kV± 10% |
|
Rise Time |
1.2 μs±30% |
|
Duration |
50 μs±20% |
|
Test Current(Short-circuit waveform) |
0.25 kA ~ 5.0 kA± 10% |
|
Rise Time |
8 μs ± 20% |
|
Duration |
20 μs ± 20% |
|
Polarity |
Positive, negative, alternative |
|
Source Impedance |
2 Ω |
|
Repetition Rate(single pulse) |
6 s ~ 99 s (The shortest time depends on test voltage) |
|
Counter |
1~ 999 |
|
Phase Angle Sync. |
0° ~ 360°(45 Hz ~ 65 Hz) |
|
Trigger Mode |
Manual, Auto, External Trigger |
|
CDN |
|
|
EUT Load Capacity |
AC 250 V, 20 A; DC 220 V, 12 A |
|
Coupling Capacitance |
9 μF(L-PE), 18μF(L-L) |
|
Coupling Resistor |
10 Ω(equivalent impedance12 Ω), 0 Ω (equivalent impedance 2 Ω) |
|
Coupling Attenuation |
<2 dB |
|
Coupling Switch |
Auto |
|
Residual surge voltage on EUT injection port |
Not exceed 15% of the maximum applied test voltage or twice the rated peak voltage of the CDN |
|
General Parameters |
|
|
Display Screen |
5.7” TFT touch screen |
|
Working Power |
AC 110 V/220 V(±10%),50 Hz /60 Hz(Default in mainland China:220 V) |
|
Fuse |
10 A |
|
Max. Power |
300 W |
|
Communication Mode |
Ethernet LAN、RJ45 |
|
External Control Mode |
25-pin parallel port cable |
|
External Trigger Input |
BNC, 5 V TTL The node is open, oscilloscope can trigger the CWS 800N when internal circuit is closed. |
|
Running Control Input |
BNC, 5 V TTL |
|
Failure Detection |
The failure information will be displayed on LCD in front panel when failure occurs and interrupt the working of instrument. |
|
Working Status Indication |
LED indication and LCD display on front panel |
|
Earthing Mode |
Flat earth line |
|
EUT Power Injection Line |
φ4 mm or φ6 mm banana plug |
|
Dimension |
6U |
|
Weight |
Approx. 44 kg |
|
Ambient Temperature |
15 ℃ ~ 35 ℃ |
|
Relative Humidity |
45% ~ 75% |
|
Atmospheric Pressure |
86 kPa ~ 106 kPa |
|
Accessories |
|
User Manual, Test line, Earth line, 3-core power line, fuses (Spare parts) |
|
Options |
|
1. External 3-phase CDN SPN series |
|
2. Isolation transformer DG-4.4 KVA |
|
3. Differential Probe VCF-80(Attenuation 1000:1) |
|
4. Wide-band Current Monitor Clamp CM 0220M |
|
5. PC control Software CoreLab Support Windows XP and Windows 7; easy operation& beautiful UI; user can easily perform customized testing sequence through each operation function and standard library; generate testing report flexibly. |