The TIS 700M10 micro-pulse interference simulator integrates the test pulse P1/2a/3a/3b power line tests required by the ISO 7637-2 standard as well as the signal line and data line tests required by the ISO 7637-3 standard. The TIS series simulators not only meet the standard requirements of numerous global automotive manufacturers, but also can be customized with various waveform simulation generators according to user needs. It has a higher pulse voltage and frequency, which can be freely set, and is used to find the sensitive points of the tested item, far exceeding the requirements of the standard.
The input of the built-in coupling network is connected to the output of the LDS series and APS series, and can be used as a unified central output port for the test equipment. Different simulators are interconnected by a data bus and connected to a remote PC via Ethernet to form a complete testing system.
Features:
> 5.7-inch color touch screen, front panel operation
Technical Parameters |
|
Micro-pulse P1 |
|
Impulse Amplitude |
3 V ~ 600 V, step 1 V |
Pulse Polarity |
Negative |
Pulse Rise Time |
0.5 μs ~ 1 μs |
1.5 μs ~ 3 μs (no load) |
|
Pulse Duration |
50 μs ± 20% (no load) |
12 μs ± 20% 2 Ω matching load |
|
1 ms ± 20% (no load) |
|
1 ms ± 20% 50 Ω matching load |
|
2 ms ± 20% (no load) |
|
1.5 ms ± 20% 10 Ω matching load |
|
0.2 ms ± 20% (no load) |
|
0.3 ms ± 20% (no load) |
|
0.5 ms ± 20% (no load) |
|
Source Impedance |
2 Ω、4 Ω、10 Ω、20 Ω、30 Ω、50 Ω |
Pulse Interval Time |
0.2 s ~ 999 s (Where the minimum interval is based on the output voltage) |
Test Number |
1 ~ 9999 |
Micro-pulse P2a |
|
Impulse Amplitude |
3 V ~ 200 V, step 1 V |
Pulse Polarity |
Positive |
Pulse Rise Time |
0.5 μs ~ 1 μs |
1.5 μs ~ 3 μs (no load) |
|
Pulse Duration |
50 μs ± 20% (no load) |
12 μs ± 20% 2 Ω matching load |
|
1 ms ± 20% (no load) |
|
1 ms ± 20% 50 Ω matching load |
|
2 ms ± 20% (no load) |
|
1.5 ms ± 20% 10 Ω matching load |
|
0.2 ms ± 20% (no load) |
|
0.3 ms ± 20% (no load) |
|
0.5 ms ± 20% (no load) |
|
Source Impedance |
2 Ω、4 Ω、10 Ω、20 Ω、30 Ω、50 Ω |
Pulse Interval Time |
0.2 s ~ 999 s (Where the minimum interval is based on the output voltage) |
Test Number |
1 ~ 9999 |
Coupled Mode |
ICC , DCC |
Electric fast transient/pulse train generator module P3a/3b |
|
Impulse Amplitude |
18 V ~ 1000 V, step 1 V |
Pulse Polarity |
Pulse 3b is positive and pulse 3a is negative |
Pulse Rise Time |
5 ns ± 30% |
Pulse Duration |
100 ns ± 30 ns |
150 ns ± 45 ns |
|
Source Impedance |
50 Ω |
Number of Pulses |
1 ~ 200 |
Pulse Group Duration |
0.1 ms ~ 10 ms |
Pulse Group Interval Time |
50 ms ~ 999 ms |
Pulse Frequency |
0.1 kHz ~ 200 kHz |
Test Duration |
1 s ~ 50000 s |
Coupled Mode |
CCC , DCC |
Free Programming Mode |
|
Impulse Amplitude |
3 V ~ 200 V, step 1 V |
Pulse Polarity |
Positive / Negative |
Impedance |
2 Ω , 4 Ω , 5 Ω ~ 100 Ω ( Step 5Ω ), 200 Ω, 400 Ω , 450 Ω |
Pulse Rise Time |
1 μs ~ 10 μs +0/-50% ( Step 1 μs ) |
Pulse Duration |
50 μs ~ 1000 μs ± 10 % ( Step 50 μs ) |
1000 μs ~ 10,000 μs ± 10 % ( Step 500 μs ) |
|
Power Disconnection Time t2 |
1 ms ~ 500 ms |
The Power Disconnection Time Point t3 |
0 μs ~ 150 μs |
Pulse Interval Time |
0.2 s ~ 999 s |
Test Number |
1 ~ 9999 |
General Parameters |
|
Display Screen |
5.7-inch TFT touch screen |
Working Power |
AC 230 V,±10%,50/60Hz |
Fuses |
6A |
Maximum Power Consumption |
300 W |
Memory Space |
Infinity ( PC ) |
Communication Methods |
Ethernet LAN, RJ45 |
Trigger Mode |
Automatic , manual , external trigger |
Network |
Built-in coupling/decoupling network 80V / 100A |
External Trigger Input |
BNC , 5V TTL, normally open node, closed trigger |
CRO Trigger Output |
BNC , 5V TTL |
Operation Control Input |
BNC , 5V TTL |
Failure Detection |
When it fails, the front panel LCD displays and the instrument stops working |
DUT Voltage Monitoring Output |
BNC , 10:1 Coaxial terminal output |
DUT Current Monitoring Output |
BNC , 40 A:1 V Coaxial terminal output |
Working Status Indication |
The front panel features LED indication and LCD display |
Grounding Connection Method |
Use a flat grounding wire |
DUT Power Supply Voltage Injection |
Red and black test leads |
Dimension |
19 inches /6U 446mm(W)*280mm(H)*612 mm(D) |
Weight |
Approx.28 Kg |
Ambient Temperature |
15℃ ~ 35℃ |
Relative Humidity |
45% ~ 75% |
Atmospheric Pressure |
86kPa ~ 106kPa |
Standard Accessories |
||||
Test line, grounding wire, fuse, RF cable, coaxial cable assembly, ZJH 100 adapter box, instruction manual, inspection report, product warranty |
||||
Optional Accessories |
||||
1 |
Automotive Immunity Test Software |
Model: AutoLab |
|
|
ISO 7637-3 Calibration Attachment |
||||
2 |
Current Injection Clamp BCIP7637-3 |
Frequency Range : 4 kHz ~ 100 MHz |
|
|
3 |
Current Injection Clamp Calibration Fixture BCICF-200 |
Frequency Range : DC ~ 200 MHz |
|
|
Natural Impedance : 50 Ω |
||||
4 |
Direct Capacitive Coupling DCC-100 nF |
Capacitance : 100 nF |
|
|
Pressure Resistance : 200 V |
||||
5 |
Direct Capacitive Coupling DCC-100 pF |
Capacitance : 100 pF |
|
|
Pressure Resistance : 200 V |
||||
6 |
Direct Capacitive Coupling DCC-470 pF |
Capacitance : 470 pF |
|
|
Pressure Resistance : 200 V |
||||
7 |
Capacitance-Coupled ClampV-EFTC |
Coupling Capacity : |
|
|
100 pF ~ 200 pF DC 5 kV |
||||
ISO 7637-2 Calibration Accessories |
||||
8 |
Pulse calibration device |
Model |
Impedance[Ω] |
|
PVK 05 |
0.5 |
|||
PVK 1 |
1 |
|||
PVK 2 |
2 |
|||
PVK 4 |
4 |
|||
PVK 10 |
10 |
|||
PVK 20 |
20 |
|||
PVK 30 |
30 |
|||
PVK 50 |
50 |