Technical Parameters |
|
Test Current Range |
100 A ~ 3000 A,± 10% |
Wavefront time: 10 μs ± 10% |
|
Half peak time: 350 μs ± 10% |
|
The wavefront time is defined as 1.25 * rise time (10% ~ 90%) |
|
Half peak time is defined as: 50% ~ 50% |
|
Output Polarity |
Positive, Negative, Alternate |
Pulse Period |
5 s ~ 180 s |
Times of Test |
1 ~ 10000 times |
Output Port |
6 mm banana socket |
Trigger Mode |
Manual, Auto,External Trigger |
External Trigger Input |
|
CRO Triggers Output |
BNC, 5V TTL |
Operation Control Input |
BNC, 5V TTL |
Communication Mode |
Ethernet,RJ45 |
D-sub 25p |
|
Safety Circuit |
Stop working when the safety loop is not closed |
General Parameters |
|
Display Screen |
5.7-inch color touch screen |
Working Power |
AC 220 V ± 10%,50 Hz |
Fuses |
10A |
Maximum Power Consumption |
1200 W |
Dimension |
19 inches/22U 600 mm (W) * 1250 mm (H) * 800 mm (D) |
Weight |
Approx. 175 kg |
Ambient Temperature |
15℃ ~ 35℃ |
Relative Humidity |
45% ~ 75%, RH (no condensation) |
Atmospheric Pressure |
86kPa ~ 106kPa |