CST 10200B is an automatic testing system designed according to the standards ISO 11452-4 and IEC 61000-4-6. The built-in high dynamic range power meter is used to monitor the test level values in the testing system. Formed a complete testing system with EMC-S software, improving the scalability and efficiency of the system. After installing the testing software, corresponding tests can be executed immediately, and the test results can be saved, printed, and shared internally within the company.
Features
> Integrated design with built-in integrated signal generator, RF power amplifier, and RF power meter
System Configuration ① Test software EMC-S ② Host CST 10200B ③ Attenuator AT200-3dB-1G-NF-NF-A ④ Attenuator AT200-30dB-4G-NF-NF-A ⑤ 50 Ω Load TF80 ⑥ Current injection clamp BCIP-400 ⑦ Calibration device BCICF-400 |
![]() |
Technical Parameters |
|
RF Signal Generator |
|
9 kHz ~ 3 GHz |
|
frequency Resolution |
0.23 Hz |
Frequency Temperature Stability |
±0.5 ppm |
Harmonic |
≤-30 dBc |
Non-harmonics |
≤-50 dBc |
Output Power Range |
120 dBm ~ 0 dBm:9 kHz ~ 500 kHz |
120 dBm ~ +10 dBm:500 kHz ~ 3 GHz |
|
Power Accuracy |
±1.0 dB |
Resolution |
0.1 dB |
Internal Modulation Source (LF) |
Sine wave:0.1 Hz ~ 500 kHz |
Triangular wave/sawtooth wave:0.1 Hz ~ 100 kHz |
|
Amplitude Modulation (AM) |
Modulation depth: 0% ~ 100% |
Modulation rate: 1 Hz ~ 1 MHz |
|
Maximum frequency offset: 5 MHz |
|
Modulation rate: 1 Hz ~ 1 MHz |
|
Modulation phase 0° ~ 360°; 1 Hz ~ 1 MHz |
|
Pulse Period |
200 ns ~ 160 s |
Pulse Width |
100 ns ~ 85 s |
N (female) |
|
<1.5:1 |
|
Power Amplifier |
|
10 kHz ~ 500 MHz |
|
1 dB Gain |
53 dB ± 2 dB (200 W) |
VSWR |
<1.5:1 |
Output Impedance |
50 Ω |
Power Meter (built-in 3-channel power meter) |
|
9 kHz ~ 3 GHz |
|
-60 dBm ~ +20 dBm |
|
Accuracy |
±0.2 dB |
Input Interface |
N (female) |
VSWR |
<1.1:1 |
General Parameters |
|
Working Power |
AC 220 V ±10%,50/60Hz |
Maximum Power Consumption |
500 W |
Dimension |
19 inches/22U 600 mm (W) * 1250 mm (H) * 800 mm (D) |
Weight |
Approx. 45 kg |
Ambient Temperature |
15℃ ~ 35℃ |
Relative Humidity |
45% ~ 75%, RH (no condensation) |
Atmospheric Pressure |
86 kPa ~ 106 kPa |
Standard Accessories |
|||
Power Cord, Fuse, Attenuator, USB Cable, Flat Grounding Wire, RF Cable,Calibration Report, Product Warranty, Operation Instructions |
|||
Optional Accessories |
|||
ISO 11452-4 BCI Test Item Equipment Accessories |
|||
1 |
Testing Software EMC-S BCI |
Supports Windows 10 system, designed for CST series RF conducted immunity PC testing software, supports USB communication mode, and enables remote calibration and testing operations. |
|
2 |
Attenuator AT200-3dB-1G-NF-NF-A |
Attenuation: 3 dB,Power: 200 W |
|
3 |
Attenuator AT200-30dB-4G-NF-NF-A |
Attenuation: 30 dB,Power: 200 W |
|
4 |
50 Ω Load TF80 |
Impedance: 50 Ω,Power: 80 W |
|
5 |
Current Injection Clamp BCIP-400 |
Frequency: 4 kHz ~ 400 MHz |
|
6 |
Calibration Device BCICF-400 |
Frequency:DC ~ 400 MHz |
|
7 |
Current Probe TWCM-500 |
Frequency: 1 kHz ~ 500 MHz |
|