Technical Parameters |
|
Parameters of Electrostatic Gun |
|
GB/T 19951:2019、ISO 10605:2023 |
|
Voltage Range |
0.2 kV ~ 30 kV(± 5%) |
Voltage Resolution |
100 V step |
Polarity |
Positive/Negative/ alternate |
Maintain Time |
5 s ~10 s |
Discharge Electrode |
Air discharge round head/contact discharge pointed head |
RC Module |
150 pF/330 ohm |
RC Module Recognition |
Automatically recognize and display numerical values |
Control Mode |
Touch screen, trigger button, fiber optic remote control |
Repetition Frequency |
Single, 0.1 Hz, 0.2 Hz, 0.5 Hz, 1 Hz, 2 Hz, 5 Hz, 10 Hz, and 20 Hz |
Trigger Method |
Automatic and manual |
Pulse Counter |
1 ~ 9999 |
Scheduling Test |
Up to 4 scheduling levels, tested in sequence |
TDC Counting Function |
Count once when the voltage of the gun head is below the set voltage threshold |
Self Inspection |
Before use, the self check function can be used to automatically verify |
Temperature and Humidity |
Built in temperature and humidity meter, can be used for environmental recording and instrument protection |
Battery Pack Parameters( Optional Accessories Battery Pack TST231–3S1P) |
|
Battery Type |
Lithium battery |
Module Voltage |
11.1 V |
Capacity |
27 Wh |
Battery Life |
Contact discharge 8 kV, 1 Hz, alternate , about 6 hours |
Battery Charging Time |
About 4 hours, fully charged automatic protection |
Cycle Life |
Charging and discharging times 300 times>80% battery capacity |
General Parameters |
|
Display |
3.5-inch color screen |
Scope of Working Power Supply |
100 V ~ 240 V(±10%) 50/60 Hz |
Language |
Chinese and English |
Brightness Setting |
0 ~ 100% brightness setting |
Screen off Setting |
Automatically turn off screen without operation: 5 min/10 min/15 min/30 min/never |
Record Logs |
Record the last 4 sets of experimental parameters |
Communication Method |
Fiber optic communication |
Instrument Grounding Connection Method |
4 mm banana socket |
Host Size |
207 mm(W)*160 mm(H)*310 mm(D) |
Instrument Weight |
About 7.35 kg (including guns) |
Ambient Temperature |
5℃ ~ 40℃ |
Relative Humidity |
20% ~ 80% ,RH(no condensation) |
Atmospheric Pressure |
86 kPa ~ 106 kPa |
Standard Accessories |
|||
1 |
RC resistance Capacitance Module 150 pF / 330 ohm |
Model:30C150R330 |
|
2 |
Gun Head Module |
Model:EDS MAX30 - TM330 |
|
3 |
Air Discharge Gun Head |
Model:EDS MAX20 - AirTip |
|
4 |
Contact Discharge Gun Head |
Model:EDS MAX20 - ConTip |
|
5 |
Electrostatic Ggun Instrument Box |
Model: EDSMAX30-00 V1.0 |
|
6 |
Discharge Return Route |
Model:CSX210GX2.5HJ,2 pieces |
|
7 |
Factory Report |
1 copy |
|
8 |
Operation Manual |
1 copy |
|
Optional Accessories |
|||
1 |
Resistance Capacitance Module |
|
|
50 pF / 100 ohm |
Model:30C50R100 |
|
|
100 pF / 1500 ohm |
Model:30C100R1500 |
||
150 pF / 150 ohm |
Model:30C150R150 |
||
150 pF / 2000 ohm |
Model:30C150R2000 |
||
200 pF / 0 ohm |
Model:30C200R0 |
||
250 pF / 0 ohm |
Model:30C250R0 |
||
330 pF / 330 ohm |
Model:30C330R330 |
||
330 pF / 2000 ohm |
Model:30C330R2000 |
||
500 pF / 100 ohm |
Model:30C500R100 |
||
500 pF / 500 ohm |
Model:30C500R500 |
||
500 pF / 5000 ohm |
Model:30C500R5000 |
||
2 |
Air Discharge Tip 30 mm |
Model: EDS MAX30-AirTip 30 mm |
|
3 |
Gun Head Module |
Model:EDS MAX30 – TM2000 |
|
4 |
Battery Pack |
Model:TST231–3S1P |
|
5 |
Calibration Device |
Model:ESD-CALA |
|
6 |
Static Discharge Test Configuration |
Model:ESDD |
|
7 |
Attenuator |
Model:JZ602 |
|
8 |
Attenuator |
Model:JZ603 |
|
9 |
PC Communication |
Model:EDS REMOTE |
|
10 |
Immunity Testing Software |
Model:CoreLab |
|
11 |
Static Dissipation Pad |
Model:ESD-DM |
|
12 |
Insulating Pad |
Size:2000 mm*1000 mm*2 mm |
|