The S16C4000N is a new type of inrush current simulator developed in accordance with the requirements of the standards YD-T 944-2007, GB/T 18802.11-2020 and IEC 61643-11:2011. It can output a current wave of 8/20 μs, and the pulse current can reach 40 kA. Just set the test requirements on the parameter setting page, and various test processes can be automatically executed.
It has the advantages of high system integration, intelligent control, simple operation, and time-saving for testing.
Features:
> 5.7-inch color touch screen front panel operation
Technical Parameters |
|
Test Current range |
2 kA ~ 40 kA ,±10% |
Charging Voltage |
≤ 16 kV |
Current Waveform |
Wavefront time: 8
μs± 10% |
Polarity |
Positive, negative, alternative |
Source Impedance |
≤ 0.4 Ω |
Repetition Rate (single pulse time) |
14 s ~ 200 s(The shortest time depends on the test current value) |
Test Number |
1 ~ 999 |
Trigger Mode |
Manual, automatic, external trigger |
Built-in Coupling/Decoupling Network |
|
EUT Carrying Capacity |
Three-phase five-wire AC 400 V (line voltage) /100 A (fully compatible with current) |
EUT Power Switching Mode |
Automatic switching |
EUT Coupling Path |
Any combination path of L1, L2, L3, N, and PE |
Coupled Mode |
GDT gap coupling |
Decoupling Method |
LC decoupling, decoupling inductance < 0.5 mH |
General Parameters |
|
Display Screen |
5.7-inch TFT touchscreen |
Power Supply |
AC 220 V,±10%,50/60 Hz |
Fuse |
10A |
Max. Power Consumption |
1500 W |
Communication Mode |
Ethernet LAN |
External Control Mode |
25-needle parallel thread |
External Trigger Input |
BNC, 5 V TTL |
Operation Control Input |
BNC, 5 V TTL |
Grounding Mode |
Use a flat grounding wire |
Dimension |
19 inches /35U rack 680mm(L)*800mm(W)*1750mm(H) |
Weight |
Approx. 393 kg |
Ambient Temperature |
15℃ ~ 35℃ |
Relative Humidity |
45% ~ 75%(no condensation) |
Atmospheric Pressure |
86 kPa ~ 106 kPa |