Itroduction:
The conducted immunity tester CST 20150D is designed according to IEC 61000-4-39 for short-range radiated field immunity tests with frequencies from 9kHz ~26 MHz. The test equipment consists of a signal generator, a wideband power amplifier (Class A) and a power meter with high dynamic range integrated in one device. All test equipment is controlled by PC software, with functions such as saving test results.
Features:
> All-in-one design, built-in signal generator and power meter
> Remote control via PC software
> IEC 61000-4-39 compliant
> IEC 61000-4-6 compliant
|
Technical Parameters |
|
|
RF Signal Generators |
|
|
Frequency range |
9 kHz-3 GHz |
|
Frequency Resolution |
0.23 Hz |
|
Frequency-Temperature Stability |
±0.5 ppm |
|
Harmonic wave |
≤-30 dBc |
|
Non-harmonic |
≤-50 dBc |
|
Output power range |
-120 dBm~0 dBm(9 kHz ~ 500 kHz) |
|
Power Accuracy |
±1.0 dB |
|
Resolution |
0.1 dB |
|
Internal Modulation Source (LF) |
sinusoid 0.1
Hz~500 kHz; |
|
Amplitude Modulation (AM) |
Modulation depth
0%~100%; |
|
Frequency Modulation (FM) |
Resolution: 5
MHz; |
|
Phase Modulation (ФM) |
Modulation phase 0°~360°; 20 Hz~1 MHz |
|
Pulse Period |
200 ns ~ 160 s |
|
Pulse Width |
100 ns ~ 85 s |
|
Output Interface |
N (Female) |
|
VSWR |
<1.5:1 |
|
Power Amplifier |
|
|
Frequency Range |
9 kHz ~ 230 MHz |
|
Gain |
52.3 dB±1 dB (170 W) |
|
1 dB gain |
51.8 dB±1 dB (150W) |
|
VSWR |
<1.5:1 |
|
Output impedance |
50 Ω |
|
Output interface |
N (Female) |
|
Power Meter (built-in 2-channel power meter) |
|
|
Frequency range |
9 kHz ~ 6 GHz |
|
Test level |
-50 dBm ~ +20 dBm |
|
Accuracy |
±0. 2 dB |
|
Input interface |
N(Female) |
|
VSWR |
<1.1:1 |
|
General Parameters |
|
|
Operating Power Range |
220 V ±10%,50 Hz /60 Hz±5% |
|
Maximum Power Consumption |
500 W |
|
Dimension |
6U chassis L * W * H: 450*280*620mm |
|
Weight |
Approx.20 kg |
|
Ambient Temperature |
15℃~35℃ |
|
Relative Humidity |
45%~75% |
|
Atmospheric Pressure |
86 kPa~106 kPa |
|
Standard Accessories |
||
|
Power cord, User manual, USB cable, RF cable, Flat ground cable, Fuses. |
||
|
Optional Accessories |
||
|
1 |
HFRA 5164
|
Radiating rings; |
|
2 |
NFCN 1356
|
Matching
networks; Frequency: 13.56 MHz, Impedance: 50Ω, |
|
3 |
LoopHolder 5164-39
|
Fixing Bracket: FESP 5134-1 |
|
4 |
FESP 5134-1
|
Magnetic field
probe, |
|
5 |
FESP 5132
|
Radiating ring
frequency: DC-150KHz, Diameter: 120m, |
|
6 |
FESP 5134-40
|
Magnetic field
probe, |
|
7 |
LoopHolder50
|
Fixing Bracket: LoopHolder50 |
|
8 |
Attenuators
|
Coaxial fixed
attenuator; |