Introduction:
The conducted interference sensitivity testing system CST 10500D (50M) is designed according to ISO 7637-4 and is used for RF induced conducted immunity testing with frequencies ranging from 100 kHz to 50 MHz. The testing equipment consists of a signal generator, a broadband power amplifier (Class A), and a power meter with high dynamic range integrated into one device. All testing equipment is controlled by PC software and has functions such as saving test results.
	
Features:
> Integrated design, built-in signal generator and power meter;
> Remote control through PC software;
> Compliant with ISO 7637-4 standard.
| 
				 Technical Parameters  | 
		|
| 
				 RF Signal Generator  | 
		|
| 
				 Frequency Range  | 
			
				 1 μHz~ 50 MHz  | 
		
| 
				 Frequency Resolution  | 
			
				 1 μHz  | 
		
| 
				 Frequency Temperature Stability  | 
			
				 ±1 ppm+10 pHz  | 
		
| 
				 Harmonic  | 
			
				 <-55 dBc  | 
		
| 
				 Non Harmonic  | 
			
				 <-60 dBc  | 
		
| 
				 Output Power Range  | 
			
				 ≤10 MHz:1.0 mVpp~10 Vpp  | 
		
| 
				 ≤30 MHz:1.0 mVpp~5.0 Vpp  | 
		|
| 
				 ≤50 MHz:1.0 mVpp~2.5 Vpp  | 
		|
| 
				 Power Accuracy  | 
			
				 ±1.0 dB  | 
		
| 
				 Resolving Power  | 
			
				 0.1 dB  | 
		
| 
				 Internal Modulation Source (LF)  | 
			
				 Sine wave 2 mHz~1 MHz;  | 
		
| 
				 Square wave 2 mHz~1 MHz;  | 
		|
| 
				 Triple wave/saw wave 2 mHz~1 MHz  | 
		|
| 
				 Amplitude Modulation (AM)  | 
			
				 
					Modulation depth 0%~120%;  | 
		
| 
				 Frequency Modulation (FM)  | 
			
				 
					Maximum frequency offset: 5 MHz  | 
		
| 
				 Phase Modulation (Ø M)  | 
			
				 
					Modulation phase 0 °~360 °;  | 
		
| 
				 Pulse Cycle  | 
			
				 1 μs to 500 s  | 
		
| 
				 Pulse Width  | 
			
				 0 ns~100 s  | 
		
| 
				 Output Interface  | 
			
				 N (Mother)  | 
		
| 
				 VSWR  | 
			
				 <1.5:1  | 
		
| 
				 Power Amplifier  | 
		|
| 
				 Frequency Range  | 
			
				 100 kHz ~ 50 MHz  | 
		
| 
				 Gain  | 
			
				 58.5 dB±1 dB (500 W)  | 
		
| 
				 1 dB Gain  | 
			
				 57 dB±1 dB (500 W)  | 
		
| 
				 VSWR  | 
			
				 <1.5:1  | 
		
| 
				 Output Impedance  | 
			
				 50 Ω  | 
		
| 
				 Output Interface  | 
			
				 N (Mother)  | 
		
| 
				 Power Meter  | 
		|
| 
				 Frequency Range  | 
			
				 9 kHz ~ 6 GHz  | 
		
| 
				 Test Voltage Level  | 
			
				 -50 dBm ~ +20 dBm  | 
		
| 
				 Accuracy  | 
			
				 ±0. 2 dB  | 
		
| 
				 Input Interface  | 
			
				 N (Mother)  | 
		
| 
				 VSWR  | 
			
				 <1.1:1  | 
		
| 
				 General parameters  | 
		|
| 
				 Scope of Working Power Supply  | 
			
				 AC 110 V/220 V ±10%,50 Hz /60 Hz±5% (Default AC 220 V 50 Hz in mainland China)  | 
		
| 
				 Maximum Power Consumption  | 
			
				 500 W  | 
		
| 
				 Size  | 
			
				 22U cabinet L * W * H: 1250 * 800 * 600 mm  | 
		
| 
				 Weight  | 
			
				 About 60 kg  | 
		
| 
				 Ambient Temperature  | 
			
				 15 ℃~35 ℃  | 
		
| 
				 Relative Humidity  | 
			
				 45%~75%  | 
		
| 
				 Atmospheric Pressure  | 
			
				 86 kPa~106 kPa  | 
		
| 
				 Standard Accessories  | 
		|
| 
				 Attenuator, Power Cord, USB Cable, Flat Grounding Wire, Factory Report, RF Cable, Fuse, Instruction Manual.  | 
		|
| 
				 ISO 7637-4A Wave Test Item Equipment Accessories  | 
		|
| 
				 Attenuator  | 
			
				 40 dB/200 W frequency range DC~1 GHz  | 
		
| 
				 
					Balanced/Unbalanced   | 
			
				 
					TBT-500: 500 V;  100 kHz ~ 50 MHz;   | 
		
| 
				 High Voltage Artificial Network  | 
			
				 
					TANHV 200:100 kHz ~ 150
  MHz;  200 A;  | 
		
| 
				 50 Ω Load  | 
			
				 50 Ω/80W frequency range DC~1 GHz  | 
		
| 
				 High Voltage Shielding Cover  | 
			
				 HVSE 400  | 
		
| 
				 High Voltage Battery Load  | 
			
				 7637-4R500/120 3000 W  | 
		
| 
				 Testing Software  | 
			
				 EMC-S 7637-4  | 
		
| 
				 Test environment  | 
		|
| 
				 Conducted indoors without shielding  | 
			
				 Test table:2,400 mm *1,000 mm *900 mm  | 
		
| 
				 Grounding reference board:2,400 mm *1,000 mm *1,200 mm  | 
		|