Technical Parameters |
|
|
Standard |
EN/IEC 61000-4-5 |
|
Test voltage |
MAX 6.6 kV(1.2/50μs) |
|
Test current |
MAX 3.3 kA(8/20μs) |
|
Coupling port |
L1(DC+), L2, L3, N(DC-), PE |
|
Coupling path |
Lx – Lx/N line to line Lx/N – PE line to PE |
|
Coupling switching mode |
Manual |
|
Coupling capacitance |
9 μF, 18 μF |
|
Coupling resistance |
10 ohm, 0 ohm |
|
EUT load capacity |
MAX AC 450 V (Lx-Lx) 32 A MAX AC 250 V (Lx-N/PE) 32 A MAX DC 220 V 16 A |
|
Residual pulse voltage at the injection of EUT |
Less than 15% of test pulse voltage or 2 times rated voltage of CDN |
|
General Parameters |
|
|
Work Power Supply |
AC 110 V / 220 V±10%, 50 Hz / 60 Hz (AC 220 V in China) |
|
Fuse |
6 A |
|
Max Power |
100 W |
|
Grounding mode |
Banana line |
|
Dimension |
6 U |
|
Weight |
Approx.38 kg |
|
Ambient Temperature |
15 ℃ ~ 35 ℃ |
|
Relative Humidity |
45% ~ 75% |
|
Atmospheric Pressure |
86 kPa ~ 106 kPa |
|
Standard Accessories |
|
User manual, Fuse, power cord, Test wire, Factory report, Grounding wire |
|
Optional Accessories |
|
CWS 600X: Combination wave lightning surge simulator, as per IEC 61000-4-5, Maximum voltage can reach 6.0 kV(1.2/50μs), 3.0 kA(8/20μs) |
|
CCS 600: Combined immunity tester, as per IEC 61000-4-5, Maximum voltage can reach 6.0 kV(1.2/50μs), 3.0 kA(8/20μs) |
|
VCF-80 Differential probe VCF-80 test voltage: 8 kV (Attenuation 1000:1) |
|
CM 0220M Broadband current monitoring pliers : CM 0220M(Attenuation : 0.01 V/A) |