EFTN 48100TM Manual three-phase coupling/decoupling network is meeting IEC 61000-4-4 requirements, and has the characteristics of good reliability, stable performance and convenient use. Maximum EUT load capacity: AC 480 V, 100 A.
	
  
	Features:
 > EUT supply can reach MAX AC 480 V;
 > Maximum current can reach 100 A;
 > Maximum pulse voltage can reach 4 kV;
 > Manually select the coupling decoupling path; 
| Technical Parameters | |
| EUT supply voltage | MAX 480 VDC | 
| EUT current | MAX 100 A | 
| Burst voltage | MAX 4 kV | 
| Coupling path | L1, L2, L3, N, PE any line coupling | 
| Coupling switching mode | Manual | 
| Coupling capacity | 33nF | 
| Residual pulse voltage at the injection of EUT | Less than 10% of test pulse voltage | 
| Grounding mode | 4mm banana line | 
| Burst INPUT port | Coaxial cable | 
| EFT INPUT mode | Single or multi-line simultaneous injection | 
| General Parameters | |
| Cabinet size | 4 U 450×192×610 mm | 
| Weight | Approx.35 kg | 
| Ambient Temperature | 15 ℃ ~ 35 ℃ | 
| Relative Humidity | 45% ~ 75% | 
| Atmospheric Pressure | 86 kPa ~ 106 kPa | 
| Standard Accessories | 
| User manual, Fuse, Three-core power cord, Test wire, Coaxial cable, Ground wire | 
| Optional Accessories | 
| TFB 500: input impedance 50 Ω, output impedance 50 Ω, attenuation 500:1 ; | 
| TFB 1000: input impedance 1000 Ω, output impedance 50 Ω, attenuation 1000:1 ; | 
| Coaxial adapter: BNC-FFM | 
| High voltage RF connector : SHV-BNC-JJ |