>Ethernet and RJ45 interface for PC remote control and test report printing;
|
Test 1: Technical Parameters for High-frequency Pulse Voltage Waveform |
|
|
Output Voltage (VIp) |
73 V±2 V(connected to 25 Ω±0.5 Ω load) 80 V±2 V (connected to 1 kΩ±0.02 kΩ load) |
|
Rise Time (tr) |
≤10 μs |
|
Time Constant (τ) |
52 μs±5 μs |
|
Pulse Repetition (t) |
5 ms |
|
Test Time |
10 min |
|
Test 2: Technical Parameters for Giant Pulse Voltage Waveform |
|
|
Output Voltage (VGP) |
100 V±2 V(connected to 25 Ω±0.5 Ω load) 110 V±2 V(connected to 1 kΩ±0.02 kΩ load) |
|
Rise Time tr |
≤1 ms |
|
Time Constant (τ) |
0.188 s±0.004 s |
|
Pulse Repetition |
1 min |
|
Counter |
1-99 |
|
Test 3: Technical Parameters for High-frequency Pulse + Surge Voltage |
|
|
High-frequency Pulse |
|
|
Pulse Voltage Peak Value (VIp) |
73 V±2 V(connected to 25 Ω±0.5 Ω load) 80 V±2 V(connected to 1 kΩ±0.02 kΩ load) |
|
Rise Time (tr) |
≤10 μs |
|
Time Constant (τ) |
52 μs±5 μs |
|
Pulse Repetition (t) |
5 ms |
|
Surge Voltage |
|
|
Output Voltage Peak |
30 V (+0,-1V) |
|
Pulse Duration |
300 ms |
|
Pulse Repetition |
1 min |
|
Counter |
10 s |
|
Calibration Resistor |
25 Ω±0.5 Ω, 1 kΩ±0.02 kΩ |
|
DUT Load(optional) |
30 A, 50 A, 75 A, 100 A |
|
General Parameters |
|
|
Working Power Supply |
AC 110V/220V±10%,50/60Hz±5% (AC 220V 50Hz in mainland China by default) |
|
Ambient Temperature |
5℃ ~ 23℃ |
|
Relative Humidity |
25% ~ 70% |
|
Atmospheric Pressure |
86 kPa ~ 106 kPa |
|
Dimension |
6U |
|
Weight |
Approx. 50 kg |
|
Standard Accessories |
|
Test Line, Power Cord, Fuse (spare parts), Instruction Manual, Calibration Load R25 Ω, Calibration Load R1000 Ω |
|
Options Accessories |
|
Autolab Control Software |