Waveforms:
|
QC/T 727 Type A-1 (JASO Type A-1) |
|
|
Pulse Amplitude - Vp |
80 V |
|
Tolerance (Vp) |
≤10% |
|
Rise Time - Tr(Vp) |
<1 μs |
|
Decaying Time Constant - τ |
200000 μs |
|
Output Impedance- R1 |
0.8 Ω |
|
Number of Pulses |
1 |
|
Polarity |
Positive |
|
QC/T 727 Type B-1 (JASO Type B-1) |
|
|
Pulse Amplitude - Vp |
80 V |
|
Tolerance (Vp) |
≤10% |
|
Rise Time - Tr(Vp) |
<1 μs |
|
Decaying Time Constant -τ |
60000 μs |
|
Output Impedance - R1 |
8 Ω |
|
Number of Pulses |
100 |
|
Repetition Frequency |
1/30 Hz |
|
Polarity |
Negative |
|
QC/T 727 Type C-1 (JASO Type D-1) |
|
|
Pulse Amplitude - Vp |
110 V |
|
Tolerance (Vp) |
≤10% |
|
Rise Time - Tr(Vp) |
<1 μs |
|
Decaying Time Constant -τ |
400000 μs |
|
Output Impedance- R1 |
1.5 Ω |
|
Number of Pulses |
1 |
|
Polarity |
Positive |
|
QC/T 727 Type D (JASO Type E) |
|
|
Pulse Amplitude - Vp |
– 320 V |
|
Tolerance (Vp) |
≤10% |
|
Rise Time - Tr(Vp) |
<1 μs |
|
Decaying Time Constant -τ |
26000 μs |
|
Output Impedance - R1 |
210 Ω |
|
Number of Pulses |
100 |
|
Repetition Frequency |
1/30 Hz |
|
Polarity |
Negative |
|
General Parameter |
|
|
Power Supply |
AC 110 V / 220 V±10%, 50 Hz /60 Hz (±5%) (AC 220 V 50 Hz in mainland China) |
|
Ambient Temperature |
15 ℃ ~ 35 ℃ |
|
Relative Humidity |
45% ~ 75% |
|
Atmospheric Pressure |
86kPa ~ 106kPa |
|
Dimension |
2*6U rack(450×600×266 mm) |
|
Weight |
Approx. 60 kg |
|
OPTIONAL MODELS |
|
|
LDS 300N30D &LDS 300D |
DUT Max. power supply:60 V 30A |
|
LDS 300N50D &LDS 300D |
DUT Max. power supply:60 V 50A |
|
LDS 300N75D &LDS 300D |
DUT Max. power supply:60 V 75 A |
|
LDS 300N100D &LDS 300D |
DUT Max. power supply: 60 V 100 A |
|
Standard Accessories |
|
|
Test line, Earth line, Radio frequency cable, Power supply line, Fuses (spare parts), User manual |
|