Technical Parameters |
|
|
Test Voltage |
Max 6 kV (the actual output depends on the set value of the generator) |
|
Phase Sync. |
Any L-L, L-PE at any phase angles between L1, L2, L3, N, PE |
|
Coupling Paths |
Any two lines between L1, L2, L3, N, PE |
|
Coupling Path Switching Method |
Automatic |
|
Coupling Capacitor |
3 μF |
|
Coupling Resistor |
5Ω, 12Ω, 27.5Ω, 30Ω (use standard types or user-defined, depending on the internal impedance of the generator) |
|
Coupling Attenuation |
<2 dB |
|
Residual Pulse Voltage At The EUT Injection Terminal |
<15% of test voltage or rated peak voltage of the CDN |
|
General Parameters |
|
|
Operating Power Supply |
AC 110 V / 220 V ±10%, 50/60 Hz ±5% (Default setting as AC 220 V, 50 Hz for Mainland China) |
|
Fuse |
6 A |
|
Max Power |
200 W |
|
Auxiliary Port |
D-sub 25p |
|
Operating Status Indicators |
Front panel LED |
|
Grounding Method |
Grounding strap |
|
Dimension |
19”, 6 U |
|
Weight |
Approx 30 kg |
|
Operating Temp. |
15℃ - 35℃ |
|
Operating Humidity |
45% - 75% |
|
Operating Air Pressure |
86 kPa – 106 kPa |
|
Standard Accessories |
|
|
Three-Core Power Cable |
1 pc |
|
Testing Wire |
1 set |
|
Grounding Strap |
1 pc |
|
Fuse |
1 pc |
|
Co-Axial Wire |
1 pc |
|
Factory Test Report |
1 pc |
|
User Manual |
1 pc |
|
Optional Generators & Accessories |
|
|
CWS 600x |
Combination Wave Simulator in compliance with IEC 61000-4-5, Surge max voltage 6 kV (1.2/50 μs), 3 kA (8/20 μs); |
|
CWS 800x |
Combination Wave Simulator in compliance with IEC 61000-4-5, Surge max voltage 8 kV (1.2/50 μs), 4 kA (8/20 μs); |
|
CCS 600x |
Combination Immunity Test Simulator in compliance with IEC 61000-4-4/-5/-8/-9/-11/-29, output max voltage 6 kV (1.2/50 μs), 3 kA (8/20 μs); |
|
EFT 500x |
EFT Simulator in compliance with IEC 61000-4-4, max voltage 4.8 kV |
|
VCF-80 |
HV differential probe, for calibration of Surge generator (open-circuit voltage waveform); test voltage max 8 kV, attenuation: 1000:1; |
|
TR 5025 |
HV current transducer, for calibration of Surge generator (short-circuit current waveform); Test current max 20 kA, attenuation 100:1; |
|
Calibration Kit for EFT Generators |
TFB 50: input impedance 50 Ω, output impedance 50Ω, attenuation 55 dB; TFB 1000: input impedance 1000 Ω, output impedance 50Ω, attenuation 60 dB; Supplied with network adaptors and tool box. |