Home|product
Chinese
search
x
    Product Menu

    PRODUCTS

    EMC General Test Equipments
    + Multifunctional Immunity Simulator
    + ESD Simulators
    + EFT/Burst Simulators
    + Surge Simulator
    + CDN for Power Line in Transient Immunity Test
    + CDN for Communication Cable in Transient Immunity Test
    + Radio-Frequency Conducted Simulator
    + CDN for RF Conducted Immunity Test
    + EM Clamp
    + Power Frequency Magnetic Field Simulator
    + AC/DC Magnetic Field Simulator
    + Pulse Magnetic Field Simulators
    + Damped Oscillatory Magnetic Field Simulator
    + Power Fail Simulator
    + DC Power Fail Simulator
    + Ring Wave Simulators
    + Fast/Slow Damped Oscillatory Wave Simulator
    + Low Frequency Conducted Immunity Simulator
    + Software
    Automotive EMC Test Equipments
    + Automotive ESD Simulator
    + Transient Immunity Simulator
    + Automotive Load Dump Simulator
    + Automotive Voltage Variation Simulator
    + Vehicle-mounted Arbitrary Waveform Simulator
    + ISO 7637-4
    + Automotive Transient Disturbance Simulator
    + Automotive BCI Test System
    + Low Frequency Magnetic Field Immunity Test System
    + Automobile Transient Pulse Simulator
    + High Voltage Noise Simulator
    + Vehicle Power Supply Circuit Surge Simulator
    + Vehicle Multimedia Voltage Disturbance Simulator
    + Ripple Signal Generator
    + Voltage Ripple Disturbance Simulator
    + Electro-mobile Vehicles Pulse Disturbance Generato
    + Automotive Spark Simulator
    + Electric Vehicle High Voltage Performance Test System
    + Artificial Network
    + Balanced / Unbalanced Transformers
    + Capacitance Coupling Clamp
    + Stripline
    + TEM Cell
    + Automotive Immunity Test Software
    + Calibration Accessories
    + Low-k Dielectric Material for Laboratory Test
    Military Test Equipment
    + Electrostatic Sensitivity for Electric Initiating
    + 300KV ESD Testing System
    + MIL-STD-461 Series/ GJB 151、181 Series
    + Spike Surge Voltage Simulator
    + Line Impedance Stabilization Network
    + HJB 34A
    Lightning Effect Test Equipments
    + High Voltage Attachment Points Partition Test System
    + Lightning Direct Effect Test System
    + Lightning Indirect Effect Test System for Airborn Equipment
    + Voltage Spike Test System
    + Induced Signal Susceptibility Test System
    System Integration
    + General EMI Test System
    + General EMS Test System
    + Automotive EMI Test System
    + Automotive EMS Test System
    + Military EMI Test System
    + Military EMS Test System
    + Anechoic Chamber
    High Voltage Test Equipments
    + Impulse Current Test System
    + Small impact current
    + Surge Simulator
    + Coupling /Decoupling Network
    + Decoupling Network
    + Action Load Network Power
    + SPD Testers
    + Customization for HV Test Equipment
    + Impulse Voltage Test System
    + Measurement/Control Software
    + Accessories
    Product Compliance Test Equipment
    + Product Compliance Tester for Communication Power
    + Power Induction/Contact Simulator
    + High Power Short Time Overcurrent Simulator
    + Pulse Voltage Withstand Tester
    + High Voltage Pulse Simulator
    Customization for Non-EMC Equipment
    + Switching Device for Capacitor Endurance Test
    Agency Equipment
    + EMI Receiver
    + Power Amplifier
    + RF Accessories
    + Current Injection Probe
    ANSI Standards
    CISPR Standards
    EN Standards
    GB/T Standards
    GJB Standards
    IEC Standards
    ISO Standards
    ITU-TK Standards
    Other standards
    QC Standards
    SJT Standards
    TY-T Standards
    UL Standards
    YD-T Standards
    HOME>Products>Agency Equipment>Current Injection Probe >FCC Bulk Current Injection Clamp
      FCC Bulk Current Injection Clamp
      Model:

      Profile

      FCC Corporation has developed and manufactured continuous wave injection probes for more than 22 model numbers, which can meet requirements of particular users and compliance tests.
      PDFConsultation

      Online customized according to your needs>>

        Share
      • Feature
      • Standard
      • Parameter
      • Fitting
      • Services
      • Video
      FCC Corporation has developed and manufactured continuous wave injection probes for more than 22 model numbers, which can meet requirements of particular users and compliance tests. It can be used in the test in compliance with Mil-Std-461/462, RTCA/DO-160Section 20 and 22. Bellcore TR-NWT-001 089, SAEJ15447, EN 55101-4, CSEFA-2 Euro-Fighter and other susceptibility specifications.

      Low Frequency Injection:
      The injection probe with model number of F-120-1, F-120-4, F-120-4A,F-120-6 and F-120-6A can be used in impulse injection source and susceptibility monitoring probes. These probes can induce and couple the transient signals with rising time of 5 ns and half impulse width of 100 μs. When it is used as monitoring probe, the available frequency range is from 10 KHz to 200 MHz and transferrable impedance +20 dB K2 is from 200 KHz to 150 MHz.

      The Application of Bulk Current Injection Probe

      Bulk Current Injection (BCI) method is used to evaluate electromagnetic susceptibility of a wide range of electronic equipment, including automotive, avionics, computing, medical and tele-communications equipment etc. ECI method can simulate the continuous wave current produced by electrical conductors of EUT in normal operating mode. These conductors include signals, control and power supply circuits of EUT. Bulk current injection conducted immunity test methods use RF transformers to inductively couple large RF currents into conductors linking parts of electronic systems. The injection probe acts as a multiple or single primary winding and the line or circuit under test acts as a secondary winding. Injection probes can be used over the entire frequency shown in the insertion loss curve accompanying each unit.
      There are three benefits for performing compliance testing using bulk current injection. The primary benefit is that BCI test results correlate well with radiated susceptibility test results. The design engineer can evaluate the affect of injected currents on the “System” or “Subsystem” under development and the relative immunity of different designs at the prototype stage of equipment development saving significant redesign time and cost. Third, conducted immunity testing can function as an integral part of a production quality assurance program. Quality assurance engineers can use BCI to perform conducted immunity tests on 100% of all critical circuits ensuring a high level of system compliance. 

        Model No.

        Clamp Dimension(mm)

        Rated Power CW

        Insertion Loss

         

        ID

        (A)

         

        OD

        (B)

         

        Ht.

        (C)

         

         

        ≤6 dB

         

        ≤10 dB

         

        ≤15 dB

         

        ≤20dB

         

        ≤25dB

         

        F-120-1

         

        40

        127

        70

        100

         

         

        1 MHZ-125

        MHZ

         

        50KHZ-150MHZ

         

        25kHZ-1 75

        MHZ

         

        F-120-2

         

        40

        127

        70

        100

         

        500KHZ-230MHZ

         

        175KHZ-250

        MHZ

         

        90KHZ-275MHZ

         

        50KHZ-300MHZ

         

        F-120-3

         

        40

        127

        70

        125

        500

        KHZ-700

        KHZ

         

        200KHZ-15MHZ

         

        100KHZ-275

        MHZ

         

        60KHZ-300MHZ

         

        30KHZ-250MHZ

         

        F-120-3B

         

        32

        94

        64

        100

        475KHZ-

        1MHZ

         

        200KHZ-30MHZ

         

        100KHZ-275

        MHZ

         

        60KHZ-300MHZ

         

        40KHZ-350MHZ

         

        F-120-4

         

        40

        127

        70

        125

         

         

        120KHZ-125

        MHZ

         

        600KHZ-150MHZ

         

        20KHZ-175MHZ

         

        F-120-4A

         

        40

        127

        70

        200

        500KHZ-

        1MHZ

         

         

        60KHZ-125MHZ

         

         

        30KHZ-125MHZ

         

        12KHZ-175MHZ

         

        F-120-5

         

        66

        142

        54

        100

         

        200KHZ-15MHZ

         

        100KHZ-150MHZ

         

        60KHZ-200MHZ

         

        30KHZ-250MHZ

         

        F-120-6

         

        40

        127

        70

        100

         

         

        3MHZ-400MHZ

         

        400KHZ-450MHZ

         

        100KHZ-500MHZ

         

        F-120-6A

         

        40

        127

        70

        100

         

        300KHZ-275MHZ

         

        70MHZ-450MHZ

         

        30KHZ-475MHZ

         

        13KHZ-500MHZ

         

        F-120-7

         

         

        63

        153

        102

        125

         

         

        400KHZ-100MHZ

         

        100KHZ-175MHZ

         

        40KHZ-190MHZ

         

        F-120-8

         

        40

        127

        134

        200

        700KHZ-

        100MHZ

         

        300KHZ-275MHZ

         

        150KHZ-375MHZ

         

        75KHZ-400MHZ

         

        40KHZ-425MHZ

         

        F-120-8A

         

        40

        127

        134

        200

         

        200KHZ-125MHZ

         

        70KHZ-155MHZ

         

        35KHZ-165MHZ

         

        20KHZ-175MHZ

         

        F-120-8B

         

        40

        127

        134

        200

         

        350KHZ-475MHZ

         

        200KHZ-520MHZ

         

        110kHZ-540MHZ

         

        60KHZ-550MHZ

         

        F-120-9

         

        40

        127

        70

        100

         

        120KHZ-230MHZ

         

        50KHZ-275MHZ

         

        25KHZ-300MHZ

         

        13KHZ-325MHZ

         

        F-120-9B

         

        32

        94

        64

        100

         

        150KHZ-80MHZ

         

        50KHZ-200MHZ

         

        25KHZ-275MHZ

         

        15KHZ-300MHZ

         

        F-130

         

        40

        117

        38

        50

        30MHZ-4

        00MHZ

         

        10MHZ-600MHZ

         

        6MHZ-700MHZ

         

        4MHZ-725MHZ

         

         

        F-130A

         

        32

        94

        64

        50

        4MHZ-45

        0MHZ

         

        1MHZ-550MHZ

         

        700KHZ-600MHZ

         

        500kHZ-625MHZ

         

         

        F-13-1

         

        40

        127

        70

        200

        10MHZ-3

        50MHZ

         

        5MHZ-510MHZ

         

        3MHZ-550MHZ

         

        2MHZ-570MHZ

         

        1MHZ-575MHZ

         

        F-130-1A

         

        40

        127

        70

        400

        7.5MHZ-

        350

        MHZ

         

        3.5MHZ-525

        MHZ

         

        3MHZ-580MHZ

         

        1.5MHZ-600

        MHZ

         

        1MHZ-850MHZ

         

        F-130-2

         

        51

        178

        102

        700

        10MHZ-2

        50MHZ

         

        3MHZ-400MHZ

         

        2MHZ-580MHZ

         

        500KHZ-550MHZ

         

        300KHZ-570MHZ

         

        F-130-3

         

        66

        142

        54

        100

        15MHZ-2

        50MHZ

         

        7MHZ-350MHZ

         

        5MHZ-450MHZ

         

        2MHZ-500MHZ

         

         

        F-140

         

        40

        127

        70

        100

        2MHZ-35

        0MHZ

         

        900KHZ-700MHZ

         

        450KHZ-1GHZ

         

        200KHZ-1.3GHZ

         

        150KHZ-1.35GH

        Z

         

        F-140A

         

        40

        127

        70

        100

        100KHZ-

        350

        MHZ

         

        100KHZ-700MHZ

         

        100KHZ-1GHZ

         

        100KHZ-1.3GHZ

         

        100KHZ-1.35GH

        Z