Combination waveform parameters |
|
Open-circuit Voltage |
|
Peak voltage |
500V ~20kV(±10%) |
Front time |
1.2μs±(±30%) |
Duration |
50μs(±20%) |
Short circuit Current |
|
Peak current |
250A-10kA(±10%) |
Rise time |
8μs (±20%) |
Duration |
20μs(±20%) |
Virtual impedance |
2Ω±0.25Ω |
Output polarity |
Positive or negative |
Network(internal/external) |
External |
Voltage waveform parameter |
|
Output voltage |
500V ~20kV(±10%) |
Output impedance |
500Ω±10% |
Output polarity |
Positive or negative |
Output voltage waveform |
1.2μs±30%,50μs±20% |
Communication waveform parameter |
|
Output voltage |
500V~10kV ±10% |
Output polarity |
Positive or negative |
Output voltage waveform |
10/700(±20%)μs |
Output current waveform |
5/320(±20%)μs |
Output impedance |
15Ω、40Ω(25+15Ω) |
Output short circuit current |
15~250A(±10%) |
Network(external) |
Optional for two-way four-wire, four-way eight-wire CDN |
General parameters |
|
Working power supply |
AC 110V/220V (±10%),50/60Hz(AC 220V in China) |
Environment temperature |
15℃-35℃ |
Relative humidity |
45%-75% |
Air pressure range |
86kPa-106kPa |
Grounding resistor |
Less than 0.5Ω |
Dimensions |
19 inch/35U(600×800×1850mm) |
Weight |
Approx.300kg |
Waveform distortion rate <5% if without conductive dust, without fire, without explosion danger, without corroding metal and insulation gas for sine power supply waveform |
Note: because of the influence by the stray capacitance of measurement unit and signal transmission, when used in the range of below 5% of full scale, there may be a few oscillation and interference at the beginning of waveform or at the peak value position, but does not affect the normal use.
Options |
|
Oscilloscope |
MDO 3012 |
Current probe |
HILOK TR1025 10kA |
Voltage probe |
Tek P 6015A |
Peak acquisition |
Touch screen displays output(built-in) |
Test case |
PA 350 |
Control software |
MCS 3000 for remote control under windows xp,windows7 |
Measurement software |
TEST 3000,optical fiber communication |
CDN |
SGN 3820T20 three phase CDN |