	The HV high-power EFT/burst immunity test system EFT/500G& EFTN 15100T is a high-end test device, which is specially designed to meet the requirement of new energy test system and EUT with high-power load. The system features high reliability, stable performance and convenience to use. Its built-in coupling/decoupling network can couple maximum 4.8 kV pulse voltage onto mains supply system with voltage up to DC 1500 V/AC 700 V (three-phase-five-line) and current 100 A. Higher voltage and current levels are available for customer's request.
       
       Features:
       > EUT DC load capacity: DC 1500 V 100 A;
       > EUT AC load capacity: AC 700 V 100 A, three -phase five- wire;
       > EUT power automatic switching over;
       > EUT voltage and current detection;
       > Overvoltage, over-current protection;
       > Setting test voltage, polarity and phase sync angle by scheduling and fully automatic network switching over;
       > Phase angle superposition for any line;
        
	
	
| Technical parameters | |
| Electrical Fast Transient/Burst simulator EFT 500G | |
| Test voltage range | 0.25 kV ~ 4.8 kV(±10%) | 
| Polarity | +/-/alternate | 
| Source impedance | 50 Ω | 
| Pulse waveform | 5/50 ns, 50 Ω , 1000 Ω load | 
| Rise time | 5 ns±30%, 50 Ω load,1000 Ω load | 
| Pulse duration | 50 ns, ±30%, 50 Ω load, 50 ns, -15/+100 ns, 1000 Ω load | 
| Pulse frequency | 0.1 kHz ~ 1000 kHz | 
| Burst duration | 0.075 ms ~ 750 ms | 
| Burst cycle | 1 ms ~ 9999 ms | 
| Test duration | 1 s ~ 9999 s | 
| Trigger mode | Auto, manual or external | 
| Synchronization | 0°~360°, resolution 1° step or random | 
| Coupling/Decoupling Network EFTN 15100T | |
| Three-phase fully automatic CDN | Electrical Fast Transient/bust tests,voltage up to 4.2 kV | 
| EUT load capacity | Max AC 700 V 100 A 50/60 Hz three-phase five-wire; Max DC 1500 V 100 A | 
| Short-term Inrush Current | Peak value: 400 A | 
| EUT switching over method | Auto switching over | 
| Phase synchronization | Any combination of L1, L2, L3, N, PE with any phases and angles | 
| Coupling paths | Any combination of L1, L2, L3, N, PE | 
| Coupling switching over mode | Auto switching over | 
| Coupling capacitance | 33 nF | 
| Coupling attenuation | <2 dB | 
| Residual pulse voltage at the injection of EUT | Less than 15% of test pulse voltage | 
| General Parameters | |
| Cabinet size | 19”/22U | 
| Weight | Approx.100 kg | 
| Ambient Temperature | 15 ℃ ~ 35 ℃ | 
| Relative Humidity | 45% ~ 75% | 
| Atmospheric Pressure | 86 kPa ~ 106 kPa | 
| Accessories | 
| User manual, Fuse, Three-core power cord, Test wire, Coaxial cable, Ground wire | 
| Options | 
| Calibration Kit for EFT/Burst Generators TFB 50: input impedance 50 Ω, output impedance 50 Ω, attenuation 55 dB; TFB 1000: input impedance 1000 Ω, output impedance 50 Ω, attenuation 60 dB; Supplied with network adaptors and tool box. |