General
parameters
|
Display
screen
|
5.7inch
TFT Touch Screen
|
Range
of working power supply
|
AC
110 V/220 V,±10%,50/60 Hz±5%(AC 220 V / 50 Hz for
China)
|
Fuse
|
6
A
|
Max.
Power dissipation
|
200
W
|
User
storage space
|
Infinity(PC)
|
Communication
mode
|
Ethernet、RJ45
|
External
control mode
|
BNC,5
VTTL
|
CRO
trigger output
|
BNC,5
VTTL
|
Run
control input
|
BNC,5
VTTL
|
External
Sync input
|
45-65
Hz, 20-500 V between dotted end and no dot end
0-500
V among dotted end, no dot end and crate
|
Output
of Warning lamp
|
0-220
V AC 10 A/0-48 V DC 3 A
The
power supply depends on the types of external signal lamp
|
Safety
circuit
|
Stop
working when the safety loop is open circuit.
|
Failure
detection
|
LCD
will display the failure on the front panel and interrupt instrument working.
|
Instrument
working status indicator
|
LED
on the front panel indicates and LCD displays
|
Instrument
grounding connection
|
Use
flat ground wire
|
EUT
power input
|
4mm2
banana plug wire
|
Detection
output mode
|
Standard
1m coaxial cable
|
Size
of crate(W*H*D)
|
19
inch/6U
|
Weight
|
Approx.50
kg
|
Temperature
range
|
15–35
℃
|
Humidity
range
|
45%-75%
|
Air
pressure range
|
86
kPa~106 kPa
|
1.2/50us,
8/20us technical parameters
|
Test
voltage range
|
0.3
kV–6.0 kV± 10%
|
Voltage
rise time
|
1.2
us± 30%
|
Voltage
duration
|
50
us± 20%
|
Test
current range
|
0.15
kA–3.0 kA± 10%(2 ohm)
|
Current
rise time
|
8
us± 20%
|
Current
duration
|
20
us± 20%
|
Output
impedance
|
2
ohm /12 ohm
|
Output
Polarity
|
Positive,
negative, alternating
|
Repetition
rate
|
6
s-99 s (The minimum time depends on the test voltage)
|
Peak
Voltage Detection
|
BNC output from the front panel 1000 V:1 V; Real-time
display of measured values
|
Peak
Current Detection
|
BNC
output from the front panel 500 A: 1 V; Real-time display of measured values
|
Counter
|
1–999
|
Trigger
mode
|
Auto,
manual and external trigger
|
Calibration
Capacitor
|
18
μF
|
CDN
|
Built-in
CDN, 250 V AC, 16 A
|
Phase
Synchronization
|
0°
~ 360° (45 Hz ~ 65 Hz)
|
10/700us,
5/320us technical parameters
|
Test
Voltage (open-circuit voltage waveform)
|
0.3
kV – 6.0 kV± 10%
|
Voltage
rise time
|
10
us± 20%
|
Voltage
duration
|
700
us± 20%
|
Test
Current (short-circuit current waveform)
|
7.5
A ~150 A± 10%
|
Current
rise time
|
5
us± 20%
|
Current
duration
|
320
us± 20%
|
Output
impedance
|
15
ohm / 40 ohm optional
|
Repetition
rate
|
16
s-99 s (the shortest time depends on the test voltage)
|
Test
times
|
1–999
|
Trigger
mode
|
Auto,
manual and external trigger input
|