Home|product
Chinese
search
x
    Product Menu

    PRODUCTS

    EMC General Test Equipments
    + Multifunctional Immunity Simulator
    + ESD Simulators
    + EFT/Burst Simulators
    + Surge Simulator
    + CDN for Power Line in Transient Immunity Test
    + CDN for Communication Cable in Transient Immunity Test
    + Radio-Frequency Conducted Simulator
    + CDN for RF Conducted Immunity Test
    + EM Clamp
    + Power Frequency Magnetic Field Simulator
    + AC/DC Magnetic Field Simulator
    + Pulse Magnetic Field Simulators
    + Damped Oscillatory Magnetic Field Simulator
    + Power Fail Simulator
    + DC Power Fail Simulator
    + Ring Wave Simulators
    + Fast/Slow Damped Oscillatory Wave Simulator
    + Common-Mode Conducted Immunity Simulator
    + Software
    Automotive EMC Test Equipments
    + Automotive ESD Simulator
    + Transient Immunity Simulator
    + Automotive Load Dump Simulator
    + Automotive Voltage Variation Simulator
    + Vehicle-mounted Arbitrary Waveform Simulator
    + ISO 7637-4
    + Automotive Transient Disturbance Simulator
    + Automotive BCI Test System
    + Low Frequency Magnetic Field Immunity Test System
    + Automobile Transient Pulse Simulator
    + High Voltage Noise Simulator
    + Vehicle Power Supply Circuit Surge Simulator
    + Vehicle Multimedia Voltage Disturbance Simulator
    + Ripple Signal Generator
    + Voltage Ripple Disturbance Simulator
    + Electro-mobile Vehicles Pulse Disturbance Generato
    + Automotive Spark Simulator
    + Electric Vehicle High Voltage Performance Test System
    + Artificial Network
    + Balanced / Unbalanced Transformers
    + Capacitance Coupling Clamp
    + Stripline
    + TEM Cell
    + Automotive Immunity Test Software
    + Calibration Accessories
    + Low-k Dielectric Material for Laboratory Test
    Military Test Equipment
    + Electrostatic Sensitivity for Electric Initiating
    + 300KV ESD Testing System
    + MIL-STD-461 Series/ GJB 151、181 Series
    + Spike Surge Voltage Simulator
    + Line Impedance Stabilization Network
    Lightning Effect Test Equipments
    + High Voltage Attachment Points Partition Test System
    + Lightning Direct Effect Test System
    + Lightning Indirect Effect Test System for Airborn Equipment
    + Voltage Spike Test System
    + Induced Signal Susceptibility Test System
    System Integration
    + General EMI Test System
    + General EMS Test System
    + Automotive EMI Test System
    + Automotive EMS Test System
    + Military EMI Test System
    + Military EMS Test System
    + Anechoic Chamber
    High Voltage Test Equipments
    + Impulse Current Test System
    + Impulse Current Generator
    + Surge Simulator
    + Coupling /Decoupling Network
    + Decoupling Network
    + Action Load Network Power
    + SPD Testers
    + Customization for HV Test Equipment
    + Impulse Voltage Test System
    + Measurement/Control Software
    + Accessories
    Product Compliance Test Equipment
    + Product Compliance Tester for Communication Power
    + Power Induction/Contact Simulator
    + High Power Short Time Overcurrent Simulator
    + Pulse Voltage Withstand Tester
    + High Voltage Pulse Simulator
    Customization for Non-EMC Equipment
    + Switching Device for Capacitor Endurance Test
    Agency Equipment
    + EMI Receiver
    + Power Amplifier
    + RF Accessories
    + Current Injection Probe
    ANSI Standards
    CISPR Standards
    EN Standards
    GB/T Standards
    GJB Standards
    IEC Standards
    ISO Standards
    ITU-TK Standards
    Other standards
    QC Standards
    SJT Standards
    TY-T Standards
    UL Standards
    YD-T Standards
    HOME>Products>High Voltage Test Equipments>Impulse Current Test System >I type 10/350 impulse current test system LCG A series
      I type 10/350 impulse current test system LCG A series
      Model:LCG A series

      Profile

      Impulse current test system LCG A series is mainly used to simulate high current generated by lightening to check the impact on power supply system and electric appliance.
      PDFConsultation

      Online customized according to your needs>>

        Share
      • Feature
      • Standard
      • Parameter
      • Fitting
      • Services
      • Video

      Impulse current test system LCG A series is mainly used to simulate high current generated by lightening to check the impact on power supply system and electric appliance. It can conduct impulse current tests with high integration, intelligent control 

      and easy operation. There are multiple grades for output by different main circuit unit. With setting parameters on setting page, 
      it can conduct the test automatically with one button.

      > Human computer interface of colorful touch screen, easy to operate;
      > PLC control system, stable and reliable operation;
      > Different control modes: manual, automatic or programmable, as per different needs;
      > Multiple grades of output ranges, test current down to 1kA;
      > Charging mode of continuous current, effectively save energy;
      > Abnormal protection by audible and visual alarm;
      > Automatic measure and analyze parameters of different waveforms.



      • TB/T 3074
      • IEC 61643-1
      • GB/T 11032
      • GB 18802.1
      • UL1449
      • YD-T 5098
      • YD/T 1235.2

      Technical parameters 

      Item 

      10/350μs current wave 

      Output peak 

      10kA15kA25kA35kA50kA100kA

      T1 front time

      10μs(<50μS

      T2 wave tail time 

      350μs±10%

      Reversed overshoot

      none

      Front oscillatory 

      5%

      Voltage polarity

      +/-, (automatic switch)

      Waveform switch

      Automatic switch 

      Charging time

      10s~999s

      Charging voltage

       instability 

      Less than 1%

      External sync input

      50Hz

      Trigger mode

      Automatic or manual, single trigger available  

      Trigger malfunction rate 

      Less than 1%

      Trigger range 

      100% rated charging voltage  

      Phase test range 

      0360°

      Operating load test

      internal0500V5A continuous supply

      Display screen

      10 inch TFT color touch screen 

      Measurement display 

      resolution

      Better than 3%

      DUT

      MOVTVSGDTSPD, mains surge protection device 

      DUT residual voltage 

      5kV

      Current measurement

       (optional)

      Internal test box, Rogowski coil measurement, panel BNC output

      Voltage measurement 

      (optional)

      Internal test box, pure-resistance voltage divider, panel BNC output

      Oscilloscope 

      MDO3012, optional 

      Insulation strength

      ≤500V RMScommon port COMMON to ground reference PE


      General data

      Power supply

      AC220V±10%50/60Hz10A

      Temperature 

      -10-+40℃

      Humidity 

      35%-85%RHno condensation

      Ground resistance 

      No more than 0.5Ω

      Structure 

      Open style, control and base separated

      Size of test room 

      Depends on modelbase+3M*5Mcontrol

      Control table

      1.8Mwidth*1.1Mheight*1Mdepth

      No conductive dust, no fire or explosion danger, no corrosive metal and insulation air. Wave

      form of mains voltage is sine wave. The THD is <5%.


      Technical parameters of standard model  

      Model 

      LCG 10A

      LCG 15A

      LCG 25A

      LCG 35A

      LCG 50A

      LCG 100A

      Current 

      peak

      0.510kA

      115kA

      125kA

      135kA

      150kA

      1100kA

      Stored 

      energy

      36kJ

      56kJ

      100kJ

      150kJ

      200kJ

      400kJ

      Charging

       voltage

      10kV

      14kV

      14kV

      14kV

      14kV

      14kV

      Supply 

      mains

      AC220V 32A

      AC220V 50A

      AC220V 50A

      AC220V 100A

      AC220V 100A

      AC220V

       200A

      Installation 

      frame

      frame

      frame

      frame

      frame

      Split frame


      Attached table one: 

      Other test waveform and output capacity

      No. 

      Waveform 

      Type 

      Max. Output 

      peak 

      Charging voltage

      Equivalent output impedance

      D

      10/1000

      Current wave 

      30kA

      15kV

      0.5Ω

      E

      100/1000

      Current wave 

      30kA

      15kV

      0.5Ω

      P

      Other waveform can be customized  

      *Internal one waveform for each equipment. Other waveform can be customized. 

       



      Name 

      Model and description 

      Installation (connection) 

      mode

      Reference picture

      Oscilloscope 

      MDO3012

      External 


      Current probe

      TR1330,100kA

      Internal


      Attenuator 

      A1010:150Ω

      External 


      Voltage probe

      P6015A40kV Peak

      External 


      Differential

       probe

      VCF 80test up to 8kV

      External 


      PC control 

      software 

      MCS3000, programmable 

      test from PC port, support 

      Win xpWin7

      RS232


      Operating load 

      mains 

      CDN 15001500A continuous 

      current  

      External 



      Tel: +86 (0)512 6807 7192

      Video