The S6/S8/S10/S20 series are intelligent multi-functional simulators, which is designed on the basis of the 3rd generation platform of our company. It fully meets the requirements of IEC 61643-1, GB18802.1, UL1449, YD-T1235[1].2 and TB/T 3074 surge standards and used for testing of surge protective devices such as MOV, TVS and GDT etc., and lightning-proof testing of various mains or scientific research in other field. With features of high integration, intelligent control easy operation, users can perform automatic tests only through easy setting on menu.
Features:
> Color touch screen operation to monitor test operation
> Constant current charging, stable and accurate; stable output
> flexible test setup for different tests requirements
> External CDN are available on request
> Built-in high-accuracy Roosevelt coil for data acquisition waveform check
Technical Parameters |
||||||||
Model No. |
S6 |
S8 |
S10 |
S20 |
||||
Output Waveform |
8/20 μs、10/350 μs |
|||||||
Front Time T1 |
8 μs±10%、10 μs±30% |
|||||||
Wave tail time T2 |
20 μs±10%、350 μs±20% |
|||||||
Current Peak Ip |
100 A,1200 A,6 kA,10 kA |
50 A ~1500 A |
10 kA,15 kA,20 kA |
20 kA,30 kA,40 kA |
||||
Current Output Range |
10% ~100% |
50 A ~100% |
1 kA~100% |
1 kA~100% |
||||
Equivalent Output Impedance |
50 Ω,5 Ω,1 Ω,0.5 Ω |
5 Ω |
1 Ω,0.75 Ω,0.5 Ω |
1 Ω,0.75 Ω,0.5 Ω |
||||
Charging Voltage |
Up to 6 kV |
Up to 8 kV |
Up to 10 kV |
Up to 20 kV |
||||
Internal Measuring Range Grade |
I grade |
- |
III grades, automatic switch |
III grades, manual switch |
||||
Voltage Polarity |
+/- (automatic switch) |
|||||||
Impulse Interval |
10 s~999 s |
|||||||
Number of Continuous Pulses |
1~99 |
|||||||
Charging Voltage instability |
Less than 1% |
|||||||
Trigger Mode |
Automatic or manual, single trigger available |
|||||||
Trigger Malfunction Rate |
Less than 1% |
|||||||
Trigger Range |
100% rated charging voltage |
|||||||
Measurement Display Resolution |
Better than 3% |
|||||||
Insulation Strength |
≤500 V rms(common port COMMON to ground reference PE) |
|||||||
General Parameters |
||||||||
Power supply |
AC220 V(±10%),50 Hz/60 Hz,10 A |
|||||||
Ambient Temperature |
15 ℃ ~ 35 ℃ |
|||||||
Relative Humidity |
45%-75% |
|||||||
Ground resistor |
≤ 0.5 Ω |
|||||||
Dimension |
19” 6U |
19” 22U |
19” 22U |
19” 35U |
||||
Weight |
Approx. 35 kg |
Approx. 120 kg |
Approx. 120 kg |
Approx. 200 kg |
||||
No conductive dust, no fire or explosion danger, no corrosive metal and insulation air. Waveform of mains voltage is sine wave. The THD is <5%. |
||||||||
Attached Table
Test Waveform and Output Capacity |
||||||
No. |
Waveform |
Type |
Max. Output Peak |
|||
S6 |
S8 |
S10 |
S20 |
|||
A |
10/350 |
Current wave |
200 A |
1500 A |
2 kA |
5 kA |
B |
4/10 |
Current wave |
2 kA |
|
5 kA |
10 kA |
C |
8/20 |
Current wave |
10 kA |
|
20 kA |
40 kA |
D |
10/1000 |
Current wave |
100 A |
|
1 kA |
2 kA |
E |
100/1000 |
Current wave |
100 A |
|
1 kA |
2 kA |
F |
1/10 |
Current wave |
1 kA |
|
5 kA |
10 kA |
G |
2 ms |
Current wave |
50 A |
|
200 A |
600 A |
P |
Other waveform can be customized. |
Options for S10 series simulator:
Name |
Model and Parameters |
Oscilloscope |
MDO3012 |
Current Probe |
TR5056, 20 kA |
Voltage Probe |
P6015A,40 kV Peak |
Peak Acquisition System |
Internal acquisition system for voltage and current; touch screen display |
Test Box |
PA 350 |
Remote Control Software |
EMSlab, programmable test on PC port, support Win XP,Win7 |