Automatic lightening surge test system ICG UK50, it is featured with high system integration and intelligence and easy operation. Setting test requirements on parameters setting page, test can be conducted with one button. Internal components test fixture, it is easy to test. The system is mainly for performance test for surge protection device, such as TVS and gas discharging tube for II level and and III level test. It can be used in production line or product development. With standard 8/20μs/ and 10/1000μs/ surge impulse current waveform, it can also meet different test requirements with optional output waveforms and testing parameters.
> test voltage up to 1000V for air discharge and contact discharge
> Computer operation, test rate up to 7PCS/S
> German fast high power semi-conductor discharging switch
> identify DUT polarity automatically
> internal temperature sensor
> self-detection
> internal DUT box and test clamps
Technical parameters |
|
Model |
ICG UK50 |
Input mains |
AC 220V 5KVA |
Output waveform |
Current waveform: 10(-10%﹢100%)μs/1000 (±10%)μs |
Optional waveform |
8(±10%)/20(±10%)μs |
Charging voltage |
0.2~2000V |
Current peak |
3A~2000A |
Output peak resolution |
±5% |
Number of test |
1~99 adjustable |
Interval time |
1~99s adjustable |
Single recycle duration |
7s+ test duration |
Control mode |
Automatic continuous test or manual single test |
DUT polarity judgment |
Polarity can be identified automatically |
General data
Power supply
AC220V ± 10%,50/60Hz
Temperature
10-40℃,35%-85%RH(no condensation)
Dimension
1200×700×1800mm
Weight
Approx. 500kg
Technical parameters
Surge pulse
IEC 61051-1
Rise time
10μs-10%﹢100%
Duration
1000μs±10%
First measurement range
15A± 10% @1kV
30A± 10% @2kV
Second measurement range
200A± 10% @1kV
400A± 10% @2kV
Third measurement range
500A± 10% @1kV
1000A± 10% @2kV
Fourth measurement range
100A± 10% @1kV
2000A± 10% @2kV