Description:
UL 60950G is designed to test the induced and conducted disturbance on the telecom lines generated by power line. It meets the requirements of UL60950. It can detect and measure all the conditions of generator, such as current and voltage value, frequency, test condition and so on and display real-time data.
Features:
LCD display;
Embedded control system;
LCD real-time display of voltage and current;
RS 232 interface, remote control.
As per:
IEC/EN 60950
UL 60950
GB 4943-2001
YD/T 993
Technical Data |
||
Test times |
1-999 |
|
Interval time |
50s-9h99min99s |
|
Duration |
Max. 9h99min99s |
|
Test voltage |
20-600V |
|
Test mode |
1/2/3/3A/4/5 |
|
Output current |
Max.60A; overcurrent protection |
|
Display resolution |
current, voltage: better than 10%; frequency: better than 1Hz |
|
Insulation strength |
≤ 500V RMS (N-PE) |
|
General Data |
||
Operating mains |
single-phase, 220V ±5%≥25kV/A 50Hz±2% |
|
Temperature |
-10- +40℃ |
|
Humidity |
35%-85%RH (no condensation) |
|
Ground resistance |
≤0.5Ω |
|
Dimension |
1730x1200 x800mm(35Ux2) |
|
Weight |
Approx.200kg |
|
Accessories |
||
Power cord, three-core, straight,2m |
1 |
|
Industrial plug cord, three-core |
1 |
|
Industrial socket, three-core |
1 |
|
Connecting wire |
1 set |
|
Aeronautic cable |
1 |
|
Test wire,2m, (red, black and green) |
1 for each |
|
Output connecting wire, JBF6mm2x2m, red and black |
1 for each |
|
Short connecting wire,6mm2x0.135m, two ends are plug tips, black |
1 |
|
Fuse Ø6x30 40A |
3 |
|
Fuse Ø6x30 25A |
6 |
|
Fuse Ø6x30 7A |
6 |
|
Fuse Ø6x30 3A |
10 |
|
Short connecting wire,10mm2x1m, two ends are plug tips, red |
2 |
|
Ground wire, yellow and green,3m |
1 |
|
Serial connecting wire, 9-core, one end is pin, another end is socket,5m |
1 |
|
Calibration certificate |
1 |
|
User manual |
1 |
|
Test report |
1 |
Accessories |
|
Power cord, three-core, straight,2m |
1 |
Industrial plug cord, three-core |
1 |
Industrial socket, three-core |
1 |
Connecting wire |
1 set |
Aeronautic cable |
1 |
Test wire,2m, (red, black and green) |
1 for each |
Output connecting wire, JBF6mm2x2m, red and black |
1 for each |
Short connecting wire,6mm2x0.135m, two ends are plug tips, black |
1 |
Fuse Ø6x30 40A |
3 |
Fuse Ø6x30 25A |
6 |
Fuse Ø6x30 7A |
6 |
Fuse Ø6x30 3A |
10 |
Short connecting wire,10mm2x1m, two ends are plug tips, red |
2 |
Ground wire, yellow and green,3m |
1 |
Serial connecting wire, 9-core, one end is pin, another end is socket,5m |
1 |
Calibration certificate |
1 |
User manual |
1 |
Test report |
1 |