Description:

UL 60950G is designed to test the induced and conducted disturbance on the telecom lines generated by power line. It meets the requirements of UL60950. It can detect and measure all the conditions of generator, such as current and voltage value, frequency, test condition and so on and display real-time data.

Features:

LCD display;

Embedded control system;

LCD real-time display of voltage and current;

RS 232 interface, remote control.

As per:

IEC/EN 60950

UL 60950

GB 4943-2001

YD/T 993



Technical Data

Test times

1-999

Interval time

50s-9h99min99s

Duration

Max. 9h99min99s

Test voltage

20-600V

Test mode

1/2/3/3A/4/5

Output current

Max.60A; overcurrent protection

Display resolution

current, voltage: better than 10%;

frequency: better than 1Hz

Insulation strength

500V RMS (N-PE)

General Data

Operating mains

single-phase, 220V ±5%25kV/A   50Hz±2%

Temperature

-10- +40

Humidity

35%-85%RH no condensation

Ground resistance

0.5Ω

Dimension

1730x1200 x800mm(35Ux2)

Weight

Approx.200kg

Accessories

Power cord, three-core, straight,2m

1

Industrial plug cord, three-core

1

Industrial socket, three-core

1

Connecting wire

1 set

Aeronautic cable

1

Test wire,2m, (red, black and green)

1 for each

Output connecting wire, JBF6mm2x2m, red and black

1 for each

Short connecting wire,6mm2x0.135m, two ends are plug tips, black

1

Fuse    Ø6x30 40A

3

Fuse    Ø6x30 25A

6

Fuse    Ø6x30 7A

6

Fuse    Ø6x30 3A

10

Short connecting wire,10mm2x1m, two ends are plug tips, red

2

Ground wire, yellow and green,3m

1

Serial connecting wire, 9-core, one end is pin, another end is socket,5m

1

Calibration certificate

1

User manual

1

Test report

1


Accessories

Power cord, three-core, straight,2m

1

Industrial plug cord, three-core

1

Industrial socket, three-core

1

Connecting wire

1 set

Aeronautic cable

1

Test wire,2m, (red, black and green)

1 for each

Output connecting wire, JBF6mm2x2m, red and black

1 for each

Short connecting wire,6mm2x0.135m, two ends are plug tips, black

1

Fuse    Ø6x30 40A

3

Fuse    Ø6x30 25A

6

Fuse    Ø6x30 7A

6

Fuse    Ø6x30 3A

10

Short connecting wire,10mm2x1m, two ends are plug tips, red

2

Ground wire, yellow and green,3m

1

Serial connecting wire, 9-core, one end is pin, another end is socket,5m

1

Calibration certificate

1

User manual

1

Test report

1