General Description
CCS600 designed as a modular system is the most intelligent solution offering exactly what people need for full-compliant immunity tests against transient, surge and voltage dips. The max voltage is up to 6kV.
The distinct operation features, convenient DUT connection facilities, clearly arranged menu structure and display philosophy as well as the pre-programmed standard test routines make testing easy, reliable and safe. Extendable by a variety of test accessories, the CCS600 is the best solution for fully compliant immunity test and used for three-phase applications up to 100A.
Features
5.7 inch color touch screen
Built-in multifunctional modular system
Internal single-phase CDN ,AC 250V/16A,DC 250V/16A
Data acquisition of surge voltage and current
External three-phase CDN
Ethernet, RJ45, PC remote control, test report documentation and print
Surge failure detection
As per:
EN/IEC 60255-22-5
EN/IEC 61000-4-4
EN/IEC 61000-4-5
EN/IEC 61000-4-8
EN/IEC 61000-4-9
EN/IEC 61000-4-11
EN/IEC 61000-4-12
EN/IEC 61000-4-29
EN/IEC 61008-1
EN/IEC 61009-1
EN 61543
ANSI/IEEE C62.41
General Data |
||||||
Display |
5.7inch TFT color touch screen |
|||||
Power supply |
AC 110V/220V, ±10%, 50/60Hz±5% |
|||||
Fuse |
6A |
|||||
Max power consumption |
200W |
|||||
Memory space |
Infinite |
|||||
Communication mode |
Ethernet ,RJ45 |
|||||
Auxiliary interface |
D-sub 25p |
|||||
External trigger input |
BNC, 5V TTL |
|||||
CRO output |
BNC, 5V TTL |
|||||
Input |
BNC, 5V TTL |
|||||
Synchronization |
45-65Hz,20-500V between dotted terminal &undotted terminal |
|||||
0-500V among dotted terminal, undotted terminal& case |
||||||
Warning LED |
0-220V AC10A/0-48V DC3A |
|||||
Power depends on external signal lamp |
||||||
Safety circuit |
The test only can be started when it is closed |
|||||
Failure test |
Display on LCD and interrupt the work at failure case |
|||||
Voltage monitor output |
BNC, 100:1 coaxial output |
|||||
Current monitor output |
BNC,10A:1V coaxial output |
|||||
Working indicator |
LED,LCD display |
|||||
Grounding connection |
Flat grounding line |
|||||
EUT power injection |
4mm² banana line |
|||||
Output mode |
1m coaxial cable |
|||||
Size |
19 inch/6 U |
|||||
Weight |
35kg |
|||||
Temperature |
15-35℃ |
|||||
Humidity |
45% - 75% |
|||||
Air pressure |
86kpa- 106kpa |
|||||
EFT Electrical Fast Transients Burst as per IEC 61000-4-4 |
||||||
EFT Electrical Fast Transients Burst |
||||||
Standards |
IEC/EN 61000-4-4, GB/T 17626.4 |
|||||
Test level |
0.25kV-4.4kV ±10% |
0.25kV-5kV ±10% |
||||
Polarity |
Positive, negative, alternative |
|||||
Source impedance |
50 ohm |
|||||
Pulse waveform |
5/50ns, 50 ohm, 1000 ohm with load |
|||||
Rise time |
5ns±30%,50 ohm, 1000 ohm with load |
|||||
Pulse duration |
50ns±30%, 50 ohm with load |
|||||
50ns-15/+100ns, 1000 ohm with load |
||||||
Spike frequency |
0.1kHz – 1000kHz |
|||||
Burst duration |
0.075ms- 750ms |
|||||
Repetition rate |
1ms – 9999ms |
|||||
Test duration |
1s – 9999ms |
|||||
Trigger of burst |
Auto, manual , extern |
|||||
Synchronization |
0-360°,resolution 1° |
|||||
Coupling/decoupling network |
built-in single phase CDN for CCS 600 (CCS 400) |
|||||
Surge Immunity requirements as per IEC 61000-4-5 |
||||||
Surge Immunity |
||||||
Standards |
IEC/EN 61000-4-5, GB/T 17626.5 |
|||||
Test voltage level |
0.3kV-4kV ±10% |
0.3kV- 6kV ±10% |
||||
Voltage waveform |
front time: 1.2us±30% time to half value: 50us±20% |
|||||
Test current level |
0.15kV-2kV ±10% |
0.15kV-3kV ±10% |
||||
Current waveform |
Front time:8us±20%, time to half value 20us±20% |
|||||
Source impedance |
2 ohm |
|||||
Polarity |
Positive, negative, alternative |
|||||
Coupling capacitance |
9uF, 18uF |
|||||
Coupling resistance |
10 ohm, 0 ohm or can be selected as the special requirement |
|||||
Duration |
5s-99s |
|||||
Measurements |
BNC output |
|||||
Voltage 1000V:1V |
||||||
Current1000A:1V |
||||||
Displayed on LED |
||||||
Test times |
1-999 |
|||||
Trigger mode |
Auto, manual, extern |
|||||
Synchronization |
0-360°,resolution 1° |
|||||
Coupling/decoupling network |
built-in single phase CDN for CCS 600 (CCS400) |
|||||
PFMF magnetic field test as per IEC 61000-4-8 |
||||||
PFMF magnetic field test |
||||||
Standards |
IEC/EN 61000-4-8, GB/T 17626.8 |
|||||
Magnetic field intensity |
Single-turn coil: 1-400A/m 100-400A/m(1-10s) |
|||||
Three-turn coil: 1-1300A/m 300-1200A/m(1-10s) |
||||||
Waveform |
50Hz/60Hz sine wave |
|||||
THID |
<5% |
|||||
Continuous current |
1A –120A |
|||||
Short-time current |
120A –500A |
|||||
Waveform interval |
1-9999s |
|||||
Test duration |
1- 28800s |
|||||
Trigger mode |
Auto, manual, extern |
|||||
Coil size |
1000*1000 mmor as the special requirements |
|||||
Coil shape |
Rectangle or as the special requirements |
|||||
Number of turns |
single-turn or three-turn |
|||||
Magnetic intensity |
Can be set up as scheduled |
|||||
PFM as per IEC 61000-4-9 |
||||||
PFM test |
||||||
Standards |
IEC/EN 61000-4-9, GB/T 17626.9 |
|||||
Magnetic field output |
100A/m –1200A/m |
|||||
Current output |
100A –2000A |
|||||
Waveform |
Rise time 6.4us±30% |
|||||
Test duration 16us±30% |
||||||
Synchronization |
0-360°,resolution 1° |
|||||
Polarity |
Positive, negative, alternative |
|||||
Trigger mode |
Auto, manual, extern |
|||||
Duration |
5-99s depending on current |
|||||
Test times |
1-999 |
|||||
Coil size |
1000*1000 mmor others |
|||||
Coil shape |
Rectangle or others |
|||||
Number of turns |
Single-turn |
|||||
Field intensity |
Be set up as scheduled program |
|||||
Power fail generator as per IEC 61000-4-11and IEC 61000-4-29 |
||||||
Power fail generator |
||||||
Standards |
IEC/EN 61000-4-11,GB/T 17626.11, IEC/EN 61000-4-29, GB/T 17626.29 |
|||||
EUT Max voltage |
250V AC, 250V DC |
|||||
EUT max current |
16A AC/DC continuous current |
|||||
20A last 5s,40Alast 3s,500Aimpulse current |
||||||
Mains for EUT |
single-phase, AC 230V±5%, 50/60Hz±5% |
DC 220V |
||||
EUT current and voltage measurement |
LCD display |
|||||
BNC terminal: voltage 100:1 current100A:1V |
||||||
Interrupt level |
0% |
|||||
Dip level |
0% - 100%( for accessories VVT/VMT) |
|||||
0%, 40%,70%,80%(for accessories VVT*****SF series) |
||||||
Repetition rate |
0.1-9999 cycle |
|||||
Duration |
5ms – 9999ms |
|||||
Test time |
1s – 9999s |
|||||
Rise and fall time |
1 – 5us(100Ω load) |
|||||
Voltage variation level |
0 – 100% |
|||||
Time for decreasing voltage |
500ms – 9999ms (50%-100%) or 1-5us(100Ω load) |
|||||
1000ms – 9999ms (0%- 100%) or 1-5us(100Ω load) |
||||||
Time for increasing voltage |
500ms – 9999ms (50% - 100%) |
|||||
1000ms – 9999ms (0% - 100%) |
||||||
Time for reduced voltage |
10ms – 99999,s |
|||||
Synchronization |
0-360°,resolution 1° |
|||||
Trigger |
Auto, manual, extern |
|||||
Description of internal CDN |
||||||
Model |
Features |
Remarks |
||||
CCS 600 (CCS 400) |
AC 250V, single phase,16A |
DC 250V/16A |
Basic equipment: generator, user manual, test report, cable, fuse
Accessories |
1.Surge coupling/decoupling network as per IEC 61000-4-5 |
SPN 3832T(380V32A) SPN 6932T(triphase 690V32A) |
SPN 383100T(380V100A) SPN 6916T(triphase 690V16A) |
2. EFT coupling/decoupling network as per IEC61000-4-4 |
EFTN 3832T(380V32A) EFTN 38100T(380V100A) |
3. Surge &EFT coupling/decoupling network |
SEPN 3816T(triphase 380V16A) SEPN 3832T(Triphase 380V32A) |
SEPN 6916T(triphase 690V16A) SEPN 6932T(triphase 690V32A) |
4. Coupling/decoupling network as per IEC 61000-4-5for signal lines and communication line |
(A) 4 lines CDN for communication line (B) 8 lines CDN for communication line |
5. Voltage dip test, VVT series as per IEC 61000-4-11 |
VVT 2216 220V single phase16A S unchangeable, SV changeable |
VVT 3816 380V three phase16AT1 unchangeable ,VT1 changeable voltage regulator×1 |
T3 unchangeable, VT3 changeable, voltage regulator×3 |
VVT2216SF 220V single phase16A, standard output 0%, 40%,70%,80% |
6. Voltage dip and PFMF test, VMT series as per IEC 61000-4-8& IEC 61000-4-11 |
VMT 2212SV 220V10A, changeable, PFMF1200A |
VMT 2212S 220V10A, changeable, magnetic field1200A |
7. Pulse magnetic field transducer PMC IEC61000-4-9 |
8. Capacity coupling CCC IEC61000-4-4 |
9.Magnetic field coil TC×10 single-turn coil, TC×30 three-turn coil,1×1mIEC61000-4-8 |
10.HV differential probe Model VCF-80, test voltage 8kV, attenuation ratio 1000:1 |
11.HV current sensor , model TR410 |
12. EFT calibration set, network adaptor, suitcase |
13. PC software EMSLab |
With PC installed WIN XP and WIN7, it can be easily operated to make the measurement, based on the customized test program. It can generate test report automatically. |